6 Testing & Troubleshooting
6-1
6 Testing & Troubleshooting
6.1 Testing the System
Inform the monitoring station when beginning or ending alarm system testing. It is the user’s responsibility to test the alarm system weekly
(excluding smoke detectors). Ensure that all the steps in the two tests below are followed.
Power up the system
Program options as required
Violate, then restore zones
Verify correct reporting codes are sent to the central station
Siren and Display Test
To perform a siren and display test:
1. Press [ ][8][Master Code][4]. The following occurs:
The alarm system activates the bell output on medium volume for 2 seconds followed by full volume alarm for 2 seconds. All display
lights and LCD pixels turn ON.
The Ready, Armed, Trouble and Power LEDs flash for the duration of the test.
2. To exit the function menu, press [#].
Walk Test
Walk Test mode tests the operation of each detector in the alarm system. While in Walk Test mode, the Ready, Armed, and Trouble LED's flash to
indicate that the walk test is active. The walk test can be terminated at any time by re-entering [
][6][Master code][8] on the keypad. The alarm
system automatically terminates the walk test on completion. The panel sounds an audible warning (5 beeps every 10 seconds), beginning five
minutes before the termination of the test.
To perform a walk test:
1. Ensure that the alarm system is disarmed and the Ready light is on.
2. Press [#] and close all zones to return the alarm system to the ready state.
3. Perform an alarm system test by following the steps in the previous section.
4. Press [
][6][Master code][8] to initiate the walk test.
5. To test the zones, activate each detector in turn (e.g., open each door/window or walk in motion detector areas).
When each zone (detector) is activated, the alarm system displays “Secure System Before Arming < >”, or “Secure or Arm System”,
depending on the zone type and the siren will sound for 2 seconds. Use the [<][>] keys to view which zones are open. The message disap-
pears when all of the zones are closed.
6.2 Resetting the System to Factory Defaults
Resetting the alarm system returns it to the factory programmed defaults. All programmed information including wireless enrollment, telephone
numbers etc. will be lost.
The installer code reverts back to [5555].
The master code reverts back to [1234].
Soft Reset
1. From the “Ready to Arm” screen, press [ ][8][XXXX]. [XXXX] represents the new installer code programmed in Installer Programming to
replace the 5555 default installer code.
2. Press [999][XXXX][999] to reset the system to default settings.
Other software resets are as follows:
Panel Only [998]
Wireless Devices [996]
Hard Reset
A hard reset performs the identical function as above. It is used when the installer code is unknown or the keypad is not communicating with the
alarm system.
1. Power down the system.
2. Remove the front cover of the alarm panel.
3. On the terminal block, jumper I/O terminal 1 to I/O terminal 2 with nothing else connected to these two terminals.
4. Power up the system for 20 seconds. (5 beeps sound to indicate that the reset has been successful).
5. Power down the system and remove the jumper.
Label programming is stored in the system and locally at the keypads. To retain label programming after performing a system reset (hard or soft)
you must rebroadcast the labels by entering Installer Programming then pressing [
][998].