2 Installation
2-4
2.3 Wireless Device Enrollment
Installing a wireless device requires programming the system with the Electronic Serial Number (ESN) of the device so that it can be identified
when an event is communicated. Two-way devices must also initiate communication with the control panel to complete the enrollment process.
The control panel will then assign the device a unique system ID, device ID and encryption key. This information is sent to the device and is
stored in its memory. The system uses these ID's and encryption to communicate events.
Methods of Enrollment
Two methods of enrollment are available:
Quick Enroll – Used to enroll new devices on the system (see below for procedure). The Quick Enroll procedure performs one-way and two-
way enrolment communications in the background. The enrollment procedures for both types of devices are identical.
Manual or DLS Enroll – See Installer Programming or DLS Programming (Section [804]). Manual or DLS enrollment of wireless keys
requires the device to be physically triggered to complete the enrollment.
Enroll wireless devices in the following sequence: Keypad, Sirens, Sensors, Pendants, Wireless Keys.
Refer to the associated installation sheets for additional details on how to activate specific wireless devices.
Enrolling Wireless Keypads
When the PC9155 is first powered up a 2 minute window is established for enrolling the first keypad. The AC Power and Ready LEDs flash for
the duration of this window. The keypad must be powered up and enrolled within this period. If not (i.e., The AC Power and Ready LEDs stop
flashing) the panel must be powered down then powered up again to re-open the 2 minute enrollment window.
1. Power up alarm system.
Connect alarm system to AC Power.
The Ready and AC LEDs flash for 2 minutes.
2. Power up keypad.
Connect keypad to AC power or install new batteries.
After a few seconds the keypad may beep rapidly and the LCD displays the following: “Hold [1] and [
] to Enroll Keypad.”
•Press the [
] and [1] keys simultaneously to enroll the keypad. “WFKP Enrollment Successful” is displayed.
2. Telephone Line Wiring
Wire the incoming line (phone company) and outgoing line (premises) to the
connection terminals of an RJ31x connector as indicated. This will allow line sei-
zure if required by the alarm system. Use 24AWG minimum for wiring.
Communication formats are programmed in section [350].
Telephone call directions are programmed in sections [351]-[376].
3. Battery 4. AC Wiring
Sealed Lead Acid Battery
Model FP 1223 ................................. 12V
DC 2.3Ah@20Hr. discharge rate
Standby...............................................................................................24Hr
Battery Replacement
Removal:
(1) Disconnect the RED (+) and BLACK (-) connectors from the battery.
(2) Depress the plastic battery retainer on the right side of the battery with thumb
to free battery from the housing, then remove battery.
Replacement:
(1) Disconnect panel from AC.
(2) Remove terminal protection from battery.
(3) Install battery cable on battery spade lug terminals.
(4) Slide left side of battery [(+) terminal] under the left battery retaining bracket.
(5) Insert a slot screwdriver between the battery and right retaining bracket. Lever
the right retaining bracket to the right while pressing the battery firmly in place.
(6) Route battery cable through wire guides and connect to battery terminal.
(7) Reconnect panel to AC.
• DSC recommends battery replacement every 3-5 years.
• Dispose of battery in accordance with local regulations.
AC Transformer Requirements:
Primary: 120V
AC, 60Hz., 0.200A (For UL/ULC listed installations)
240V
AC, 50Hz., 0.100A
(Fuse: 503 Si, 250V/160mA Fast-Blo)
Secondary: 16.5V
AC/20VA
The following plug-in transformers shall be used:
North America (UL Listed Installations)
PTD1620U-CC
Canada (ULC Listed Installations)
PTD1620
Do NOT connect transformer to a receptacle controlled by a switch. Use a Class 2, power limited transformer for UL/ULC installations.
i
If the “Failed to Enroll” message is displayed perform the following:
Retry the enrollment.
Reposition the keypad closer to the control panel.
Verify that the READY and POWER LED indicators are flashing on the panel. If not, disconnect the panel from AC and DC power
sources then reconnect.
Check for RF interference. See “2.4 Wireless Device Placement Test” for more information.
Verify that the keypad is the correct model for the PC9155 System.
T-1
R-1
TIP
RING
RJ-31X
RED
GRN
BRN
GRA
Internal Transformer
Secondary Wire Run Distance
AWG Feet Meters
24
22
20
18
5.8
9.3
14.8
23.5
1.8
2.8
4.5
7.2