PC9155 Wireless Alarm System
3-1
3 Operation
3.1 Operating Modes
3.1.1 – Away Arming
Away Arming arms the entire system including the perimeter and interior devices. The Ready light must be ON to arm the system. If the Ready light
is OFF, ensure all protected doors and windows are secure or bypassed. To arm the system in the Away mode, either press and hold the Away func-
tion key for 2 seconds or enter a valid user code and leave the premises through a door programmed as Delay. Upon pressing a function key or enter-
ing an access code, the Armed light turns ON. If the Audible Exit Delay option is enabled, the keypad will beep once every second during the exit
delay (and three times a second during the last 10 seconds) to alert the user to leave. The Ready light will turn off when the Exit Delay ends.
3.1.2 – Stay Arming
Stay Arming is intended to arm the perimeter of the premises while permitting movement within the premises. The Ready light must be ON to
arm the system. If the Ready light is OFF ensure all protected doors and windows are secure or bypassed. To arm the system in the Stay mode,
either press and hold the Stay function key for 2 seconds or enter a valid user code and stay within the premises (do NOT violate a door pro-
grammed as Delay). Upon pressing a function key or entering an access code, the Armed light turns ON. If the Stay function button is used, the
keypad will not beep during the exit delay and the user can still exit the building without the system reverting to Away mode. When a user code is
used, the keypad beeps if the Audible Exit Delay option is enabled. The Ready light turns off when the exit delay ends.
3.1.3 – Night Arming
Night arming is intended to arm the perimeter and restrict movement to designated areas in the interior (e.g., hallways from bedrooms to bathrooms).
If night zones are programmed, entering [
][1] while the system is armed in stay mode will re-activate all interior zones except those programmed as
night zones. Alternatively, while the system is disarmed the Night Arm function key can be pressed for 2 seconds to arm the panel in night mode. The
Ready light must be ON (disarmed) or the system must be armed in the Stay mode to arm the system in this mode. In Night mode only night zones
(Zone definition 37) are bypassed. When activated, there are no acknowledgement beeps, the exit delay is silent and the panel logs “Armed in Night
Mode.” If there are no night zone types programmed on the system, the system arms in Away mode and the panel logs “Armed in Away Mode.
3.1.4 – Disarming
The user must enter through a door programmed as Delay. Upon entering, the keypad emits a steady entry delay tone (and a pulsing tone during
the last 10 seconds of entry delay) to alert the user to disarm the system. To disarm the system, enter a valid user code, present a proximity tag or
use a wireless key. If an alarm occurred while the panel was armed, the keypad displays “Alarm in Memory” and the zone(s) that went into alarm
during the armed period. Press the [#] key to return the keypad to the Ready state.
3.2 Language Selection
The keypad can be programmed to display messages and labels in different languages. Language can be selected before the keypad is enrolled on
the system. Perform the following when in “Ready to Arm” mode or at the Installer Programming menu:
(1) Press and hold both scroll keys [< >] simultaneously until language options are displayed.
(2) Scroll to the desired language using the scroll keys [< >].
(3) Press [
] to select the desired language.
3.3 [ ] Commands
The following is a list of the [ ] commands available and a description of each:
[
][1] Bypass (disarmed state)/Reactivate Stay/Away Zones (armed state)
[
][2] Display Trouble Conditions
[
][3] Display Alarm Memory
[
][4] Door Chime Enable/Disable
[
][5][Master/Supervisory Code] User Code Programming and Proximity Tag Enrollment
[ ][6][Master/Supervisory Code] User Functions
[ ][7][1/2] Command Outputs 1 and 2
[
][8][Installer Code] Installer Programming
[ ][9][User Code] No-Entry Arming
[
][0] Quick Arm (disarmed state)/Quick Exit (armed state)
[ ][1] – Bypass/Re-activate Stay/Away and Night Zones
Press [ ][1] to enter Bypass mode. If the Code Required for Bypass option is enabled, enter a valid user code. The keypad displays “Scroll to
Bypass Zones”. The keypad displays the programmed zone labels and includes the letter “O” in the bottom, right corner if the zone is violated or
the letter “B” if the zone is bypassed. Scroll to the appropriate zone and press the [
] key to change the bypass status (or enter the 2-digit zone
number). Once the correct zones are bypassed, press [#] to exit.
Additional Bypass Commands
Bypass Recall: In Bypass mode, press [99]. The keypad recalls the last group of zones that were bypassed.
Clear Bypass: Press [00]. The keypad clears the bypass on all zones.
Save Bypass: Press [95]. The keypad saves zones which are manually bypassed.
Recall Save: Press [91]. The keypad recalls the bypassed zones that were saved.
i
Zones must be programmed with zone definitions (05 Interior Stay/Away, 06 Delay Stay/Away, or 32 Instant Stay/
Away) for this function to work.