PC9155 Wireless Alarm System
5-25
[012] Keypad Lockout Options
This section determines how the keypad lockout function operates.
07
Keypad Buzzer Follow. The PGM output switches to ground when the keypad buzzer is activated by the events described below. The PGM output
will remain switched to ground while the keypad buzzer is active.
24-hour supervisory buzzer zone alarm No activity arm pre-alert
Entry delay • Audible exit fault
Audible exit delay Door chime
This PGM type does not activate for local key presses or trouble beeps.
08
Courtesy Pulse. This PGM output switches to ground for 2 minutes past the end of entry or exit times to allow enough time for complete entry to or
exit from the premises. If the system is armed through the No Activity Arming method this output will NOT activate.
09
System Trouble. This PGM output switches to ground when any of the selected Troubles are detected. The output will de-activate when all of the
selected Troubles are restored. The PGM attributes from this output are as follows:
1 Service Required 5 Device (Fire) Fault
2 A.C. Failure 6 Device Tamper
3 Telephone Line Fault 7 Device Low Battery
4 Communications (Failure to Communicate) 8 Loss of Clock
10
Latched System Event (Strobe). This PGM output switches to ground when any of the selected system events (alarms) occur on the system. The
PGM output will deactivate when an access code is entered to disarm the system. If an alarm activates this output in the disarmed state, the alarm will
deactivate when a code is entered during bell time-out or if the system arms after bell time-out.
This output will activate for all silent and audible alarms.
1 Burglary Delay, Interior Delay, Instant, Interior, Stay/Away, Instant Stay/Away, Night, Day Zone and 24-Hour. Burg zones
2 Fire Key, Fire zone
3 Panic Key and Panic
4 Medical Key, Medical and Emergency zones
5 Supervisory Supervisory, 24-Hour. Buzzer, Auxiliary, Freeze, and Water zones
6 Priority Gas, Heat, 24-Hour CO zones, 24-Hour Non-latching Tamper
7 Duress Duress alarms
8 Latched Follows output timer
i
This PGM output activates for alarm conditions only. Pre-alerts or delays do NOT activate the output. When this output follows the output timer, events
that have been disabled from activating the output will not restart the timer.
11
System Tamper. This PGM output switches to ground when any Tamper condition occurs on the system. If set for steady operation, this output de-
activates when all Tamper conditions on the system are restored. If this output is set for a pulsed output, the PGM output will switch to ground when a
Tamper condition occurs and remains on for the duration of the PGM output timer (programmed in section [170]). This will activate for each Tamper
condition, even if there is an unrestored Tamper condition on the system.
Tampers include zone tampers (DEOL), PC9155 case tampers, TLM trouble, RF Jam, and all zone and device tampers.
12
TLM and Alarm. The output will activate when a Telephone Line Trouble (TLM) trouble condition is present and then an alarm occurs on the system.
13-16
Future Use
17
Away Armed Status. This PGM output follows the status of the Stay/Away zones. If the system is armed with the Stay/Away zones always active,
then the Away output is active.
18
Stay Armed Status. This PGM output follows the status of the Stay/Away zones. If the system is armed with the Stay/Away zones bypassed, then the
Stay output is active.
19 Command Output #1. Entering the [][7][1] command activates the PGM type according to how the PGM attributes are configured. Refer to sec-
tions [501] and [502] for attribute information.
20 Command Output #2. Entering the [][7][2] command activates the PGM type according to how the PGM attributes are configured. Refer to sec-
tions [501] and [502] for attribute information.
21-39
For Future Use
40
Audio Verification Trigger. This PGM output activates when the conditions are ready for 2-way audio verification. This output is intended to be used
with the PC5950 module. Activation of this output will be delayed until the kiss-off of the alarm messages.
Number of Invalid Codes before Lockout
Program a number from 000 to 255 to determine the number of invalid master, user or installer access code entries to reach keypad lockout. When key-
pad lockout occurs, the system is rendered inoperative via the keypad for the programmed duration only (wireless keys and keyswitch zones will still
be able to function). When any keys are pressed, an error tone sounds. Entering 000 disables keypad lockout.
Lockout Duration
Program a time from 000 to 255 minutes to determine the length of time before lockout resets and the keypad can once again be used.
If lockout is not reached within the hour roll-over, the number of invalid attempts is reset to 0.
After a valid access code is entered, the number of invalid attempts is reset to 0.
Fire, Auxiliary and Panic keys are still active during keypad lockout.
Key presses will not reset the lockout timer.
If the lockout timer was active before powering down, the system lockout will be active for the programmed duration on power up.