PC9155 Wireless Alarm System
5-3
00 Null PGM (Not Used) TLM and Alarm
01 Fire and Burglary Output For Future Use
02 For Future Use
A
way Armed Status
03 For Future Use Stay Armed Status
04 For Future Use Command Output #1 ([*][7][1])
05 System Armed Status Command Output #2 ([*][7][2])
06 Ready To Arm For Future Use
07 Keypad Buzzer Followe
r
For Future Use
08 Courtesy Pulse For Future Use
09 System Trouble Output (with Trouble Options) For Future Use
10 System Event Output (with Event Options)
A
udio Verification Trigge
r
System Tamper (all sources: zones, keypad)
NA CP EU
ON OFF
1
999
Hardwired Zone 33 Input Enabled PGM 1 Output Enabled
2
999
Hardwired Zone 34 Input Enabled PGM 2 Output Enabled
3
For Future Use
4
For Future Use
5
For Future Use
6
A
udible Exit Fault Enabled
A
udible Exit Fault Disabled
7
For Future Use
8
Temporal Three Fire Signal Enabled Standard Pulsed Fire Signal
NA CP EU
ON OFF
1
A
rm / Disarm Squawk Enabled
A
rm / Disarm Squawk Disabled
2
For Future Use
3
RF Jam Log After 5 Minutes RF Jam Log After 20 sec
4
For Future Use
5
For Future Use
6
999
A
udible Exit with Urgency Silent Exit Delay
7
For Future Use
8
Fire Siren is Continuous Fire Siren Follows Siren Cut-Of
f
NA CP EU
ON OFF
1
999
[F] Key Enabled [F] Key Disabled
2
[P] Key Audible (Siren / Beeps) [P] Key Silent
3
999
Quick Exit Enabled Quick Exit Disabled
4
999
Quick Arming Enabled (*0 And Function Keys) Quick Arming Disabled (Funct. Keys Req. Code)
5
Code Required For Bypassing No Code Required
6
Master Code Not Changeable Master Code Changeable
7
999
TLM Enabled TLM Disabled
8
System Tamper Enabled System Tamper Disable
[013] First System Options
Opt
[014] Second System Options
Opt
[015] Third System Options
Opt
Def
000
Number of Invalid Codes Before Lockout (Valid entries are 000-255)
Def
000
Lockout Duration (in minutes) (Valid entries are 000-255)
Def
00
I/O Type (Zone 34, PGM 2) Enter Zone or PGM Definition
[012] Keypad Lockout Options
i
If Keypad Lockout is active, the system can not be disarmed with a wireless key.
40
11
[009] I/O Programming
Def
00
I/O Type (Zone 33, PGM 1) Enter Zone or PGM Definition
19
20
21-32
33
34
35
Programmable Output Options
12
13-16
17
18