5 Installer Programming
5-2
5.2 Programming Worksheets
NA
CP
EU
00 Null Zone 14 24 Hour Heat 28 Future Use
01 Delay 1 15 24-Hour Medical 29 Future Use
02 Delay 2 * 16 24-Hour Panic 30 Future Use
03 Instant * 17 24-Hour Emergency 31 Day Zone
04 Interio
r
18 Future Use * 32 Instant Stay/Away
05 Interior Stay/Away * 19 24-Hour Wate
r
33 Future Use
06 Delay Stay/Away * 20 24-Hour Freeze 34 Future Use
07 Future Use 21 Future Use 35 Future Use
08 Future Use * 22 Momentary Keyswitch Arm 36 24-Hr Non-Latching Tampe
r
09 24-Hour Supervisory (Hardwired) * 23 Maintained Keyswitch Arm 37 Night Zone
10 24-Hour Supervisory Buzze
r
24 Future Use ** 81 24-Hr Carbon Monoxide (Wireless)
11 24-Hour Burglary * 25 Interior Delay 82 Audio Verification Monito
r
12 Future Use *
26 24-Hour Non-Alarm (local alarm)
** 87 Delay 24-Hr Fire (Wireless)
13 24-Hour Gas 27 Future Use ** 88 Standard 24-Hr Fire (Wireless)
** 89 Auto Verified Fire (Wireless)
* For burglary applications only ** For residential fire applications only
Sect
NA CP EU NA CP EU
Sect
NA CP EU NA CP EU
Sub Sect.
Sub Sections [02]-[08] are reserved for future use
Bell Time Out (BTO)
004 004 004
For 4-digit codes the default is the first 4 digits.
A
AAA00
[006] Installer's Code [007] Master Code [008] Maintenance Code
i
These codes are 4 or 6-digits (programmed in section[701] Opt [5]).
Def
555555
Def
123456
Def
[09]
i
For SIA CP-01 compliant installations, the Exit Delay must be within the range of 045-255 seconds.
i
If the Exit Delay is silent (section 14, option 6 or Stay Function Key Arming) the exit delay will be twice the programmed
value but will not exceed 255 seconds (i.e., 090-255 seconds).
i
For UL installations, the Entry Delay plus the Communications Delay must not exceed 60 seconds.
Exit Delay
120 060 120
Entry Delay 2
045 030 045
[005] System Timers
Valid entries for Entry Delay are between 030-255.
[01]
Entry Delay 1
NA
030
CP
030
EU
030
00 00
32
00 00 0000 00 00
24
00
8
04 04 04
16
00 00
31
00 00 0000 00 00
23
00
7
04 04 04
15
00 00
30
00 00 0000 00 00
22
00
6
04 04 04
14
00 00
29
00 00 0000 00 00
21
00
5
04 04 04
13
00 00
28
00 00 0000 00 00
20
00
4
03 03 03
12
00 00
27
00 00 0000 00 00
19
00
3
03 03 03
11
00 00
26
00 00 0000 00 00
18
00
2
03 03 03
10
00 00
25
00 00 0000 00 00
[002] 17
00
[001] 1
01 01 01
9
[001]-[002] Zone Definitions
Zone Zone Zone Zone
Indicates default settings for North American panel
s
Indicates default settings for CP-01 complianc
e
Indicates default settings for European panel
s
A
ll Defaults are OFF unless indicated otherwis
e