6 Testing & Troubleshooting
6-4
Trouble [2] AC Failure
AC Failure
No AC at panel AC input terminals. Verify voltage measured across AC terminals is 16-18VAC.
Replace transformer if required.
Trouble [3] Telephone Line Trouble
Telephone Line Trouble
Phone line voltage at TIP, RING on main
panel less than 3V
DC.
Measure the voltage across TIP and RING on the panel:
No phone off-hook – 50VDC (approx.).
Any phone off-hook – 5VDC (approx.).
Wire incoming line directly to TIP and RING.
If trouble clears, check wiring or the RJ-31x phone jack.
Trouble [4] Failure to Communicate
Failure to Communicate
Panel fails to communicate one or more
events to central station.
Connect a handset to TIP and RING of the control panel. Monitor for the
following conditions:
Continuous dial tone
Reverse TIP and RING.
Recorded operator message comes on
Verify correct phone number is programmed.
Dial the number programmed using a regular telephone to
determine if a [9] must be dialed or if 800 service is blocked.
Panel does not respond to handshakes
Verify the format programmed is supported by the central station.
Panel transmits data multiple times without receiving a handshake
Verify that the account number and reporting codes are correctly
programmed.
Contact ID and Pulse formats
Program a HEX [A] to transmit a digit [0].
SIA format
Program a digit [0] to transmit a digit [0].
GSM/Ethernet
Refer to the TL260GS/TL265GS/GS2060/GS2065 Installation
Manual for troubleshooting actions.
Trouble [5] Device Fault
Press [5] to determine specific devices with a fault trouble
1st press - Zone Faults
2nd press - Keypad Faults
3rd press - Siren Faults
Hard-wired zone fault condition present.
A short circuit is present on one or more
zones with double end-of-line resistors
enabled.
One or more wireless devices have not
checked in within the programmed time.
Ensure fire zones have a 5.6K resistor (Green, Blue, Red)
connected.
Remove the wire leads from I/O and AUX- terminals and measure
the resistance of the wire leads.
Connect a 5.6K resistor (Green, Blue, Red) across the I/O and AUX-
terminals. Verify the trouble condition clears.
Perform a module placement test verify the wireless device is in a good
location.
If bad test results occur, test the wireless device in another location.
If the wireless device now tests good, the original mounting location
was bad.
If the wireless device continues to give bad test results replace the
wireless device.
Trouble [6] Device Tamper Press [6] to determine specific zones with a tamper trouble
1st press - Zone Tampers
2nd press - Keypad Tam-
pers
3rd press - Siren Tampers
An open circuit is present on one or more
zones with double end-of-line resistors
enabled.
A tamper condition is present on one or
more wireless devices.
Remove the wire leads from I/O and AUX- terminals and measure
the resistance of the wire leads.
Connect a 5.6K resistor (Green, Blue, Red) across the I/O and
AUX- terminals.
Verify the trouble condition clears.
Ensure device cover is secure.
Ensure device is correctly mounted for wall tamper operation,
violate, then restore the tamper.
If tamper condition persists then replace wireless device.