Alexor WT8989 Manuel d'utilisateur Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
8
11. Trouble Conditions
When a trouble condition is detected, the Trouble ( ) indicator will turn on and the keypad will beep
every 10 seconds. Press the [#] button to silence the beeps. Press [
,][2] to view the trouble condition.
The Trouble ( ) indicator will flash. Use the scroll [<][>] keys to view troubles.
12. Trouble Acknowledgement
When the Troubles Inhibit Arming feature is enabled, the Trouble Acknowledgement feature may be
used to acknowledge and override the existing troubles, so the system can be armed. To use this fea-
ture, press to enter the Trouble menu. Scroll left or right and press or
when the keypad displays, “Trouble Acknowledgement.” An override event will also be logged, thus
identifying the user. To override open, faulted or tampered zones use the Zone Bypass feature
().
13. Alarm Memory
When an alarm occurs, the Alarm Memory message will be displayed. To view which sensor(s) gen-
erated the alarm, press [
,][3]. For the system keypad use the scroll [<][>] buttons to view the sensors
in alarm memory. Press [#] to exit. To clear the memory, arm/set and disarm/unset the system.
If an alarm sounded while armed/set, the system will automatically go to alarm memory when you
disarm the system. In this instance, you should proceed with caution, as the intruder may still be
within the building/premises.
14. Door Chime
To turn the door chime function on or off, press and hold the Chime button for 2 seconds or
press [
,][4]. The system will sound 3 beeps to indicate the door chime is on, or one long tone to indi-
cate that door chime is off.
Trouble Comments Action
Alternate
Communicator Trouble
Indicates SIM Card Lock, 3G Network Trouble, Ethernet Trouble,
Central Station Receiver Trouble, Supervision Trouble, and SMS
Config Trouble. Press [<][>] to scroll through individual troubles.
Call for service.
For Ethernet Trouble
check LAN connec-
tions.
Service Required
(Press [1] for more infor-
mation)
Indicates Low Battery, System Trouble, System Tamper or RF Jam
detected.
Call for service.
Loss of AC Power If the building and/or neighbourhood has lost electrical power,
the system will continue to operate on battery power for several
hours.
Check AC connection.
Call for service.
Telephone Line Fault The system has detected that the telephone line is discon-
nected.
Call for service.
Failure to
Communicate
The system attempted to communicate with the monitoring sta-
tion but failed. This may be due to a telephone line fault.
Call for service.
Module/Sensor Fault The system is experiencing difficulties with one or more module/
sensor on the system. Continue to press [5] to navigate through
the zone, keypad, and siren fault menus.
Call for service.
Module/Sensor Tamper The system has detected a tamper condition with one or more
module/sensor on the system. Continue to press
[6] to navigate
through the zone, keypad, and siren tamper menus.
Call for service.
Module/Sensor Low
Battery
The system has detected a low battery condition with one or
more module/sensor on the system. Continue to press
[7] to
display the zone(s), wireless key(s), keypad(s), siren(s) and prox
tag(s).
See section 22.1 Siren
and Keypad Display
Test. Call for service.
Loss of Time & Date If complete power was lost (AC and Battery), the time and date
will need to be re-programmed. Press
[,].
Reprogram Time &
Date.
Blank Display / No
Response
Keypad battery may have discharged beyond the usable level. Replace battery (call
for service if trouble
not cleared).
Panel Response Not
Received message
The keypad has lost wireless communication with the panel.
Occasional display of this message may be caused by local radio
frequency interference.
If trouble persists, call
for service.