7
Door Chime
To turn the door chime function on or off, press and hold the Chime button for 2 seconds or
press . The system will sound 3 beeps to indicate the door chime is on, or one long tone
to indicate that door chime is off.
Access Code Programming
In addition to the master code, you can program up to 16 additional user access codes. If wire-
less keys have been programmed then wireless key #1 will log as User Access Code #1 (if that
access code has been programmed). User Access Codes 1-16 will correspond to wireless keys
or prox tags 1-16. Press [Master Access Code]; the armed ( ) indicator will turn on.
Enter the 2-digit number to be programmed (e.g., 06 for User Access Code 6; enter 40 for the
master access code) or press the scroll buttons to find the specific code and press
to select. Enter the new 4-digit access code. When programming is complete, enter
another 2-digit code to program or press to exit. The access codes have programmable
attributes which allow zone bypassing, duress, supervisor, remote access, or one-time use acti-
vation.
On WT5500P keypads, you will be prompted to swipe a prox tag once the last character of the
access code is entered. To delete prox tags, the associated user access code must be deleted
as described, then re-programmed if required.
Access Codes [][5][Master Code] (when disarmed)
The [][5] User’s Programming command is used to program additional access codes.
User Codes - User codes 1-16 are available for the system.
Master Code (Access Code 40) - The master code has all of the attributes listed in the Pro-
grammable Attributes list below except for Duress (2) and One-Time Use (8) and is required to
program all supervisor code attributes.
Supervisor Codes - These codes are always valid when entering the User Code Pro-
gramming or User Function sections. However, these codes can only program addi-
tional codes which have equal or lesser attributes. Once programmed, the supervisor codes
receive the master code’s attributes. These attributes are changeable. Any user code can be
made a supervisor code by enabling User Code Attribute 1 (please see below for details).
Duress Codes - Duress codes are standard user codes that will transmit the Duress Alarm
Reporting Code whenever the code is entered to perform any function on the system. Any user
code can be made a duress code by enabling User Code Attribute 2 (see below for details).
One-Time Use Code -
This code permits temporary access to the system for a 24-hour time
period. During the 24hr period, the temporary user may disarm the system once. There is no
restriction on the number of times the temporary user may arm the system during the time period.
NOTE: Duress codes are not valid when entering [][5], [][6] or [][8] sections.
NOTE: Access codes cannot be programmed as a duplicate or as a "Code +/- 1".
User Code Attributes
1. The default attributes of a new code will be the attributes of the code used to enter
whether it is a new code or an existing code being programmed.
2. System Master (Code 40) has Attribute 3 on by default.
NOTE: These attributes are not changeable.
Inherent Attributes (all codes except installer)
Arm / Disarm - Any access code will be valid for arming and disarming the system.
Command Outputs ([][7][1] and [][7][2]) - If these outputs require access code entry, any
access code is valid for performing the [][7][1-2][Access Code] functions on the system.
Programmable Attributes ([][5][Master/Supervisor Code][9][Code])
1 Supervisor Code 5-6 For Future Use
2 Duress Code 7 Bell/Siren Squawk upon Away Arming/Disarming
3 Zone Bypassing Enabled 8 One-Time Use Code
4 Remote Access
Vue de la page 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 26 27

Commentaires sur ces manuels

Pas de commentaire

Flowserve Heavy Duty Gear Override Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Hardware Flowserve Heavy Duty Gear Override.
Wir stellen 1 PDF-Handbücher Flowserve Heavy Duty Gear Override zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Bedienungsanleitung






Weitere Produkte und Handbücher für Hardware Flowserve

Modelle Dokumententyp
R5 Actuator Bedienungsanleitung   Flowserve R5 Actuator User Manual, 4 Seiten
APEX 5000 Analog Feedback Options Bedienungsanleitung   Flowserve APEX 5000 Analog Feedback Options User Manual, 4 Seiten
CENTURA Analog Output Options Calibration Bedienungsanleitung   Flowserve CENTURA Analog Output Options Calibration User Manual, 2 Seiten
CE DC Brake Bedienungsanleitung   Flowserve CE DC Brake User Manual, 4 Seiten
ESP-DC Electronic Servo Positioner Bedienungsanleitung   Flowserve ESP-DC Electronic Servo Positioner User Manual, 5 Seiten
Centura Electric Actuator Bedienungsanleitung   Flowserve Centura Electric Actuator User Manual, 1 Seiten
Nuclear Qualified Pneumatic Actuator Bedienungsanleitung   Flowserve Nuclear Qualified Pneumatic Actuator User Manual, 4 Seiten
Field Mounting Kits Bedienungsanleitung   Flowserve Field Mounting Kits User Manual, 1 Seiten
MX Limitorque Bedienungsanleitung   Flowserve MX Limitorque User Manual, 164 Seiten
Centura CE Extra-Switch Bedienungsanleitung   Flowserve Centura CE Extra-Switch User Manual, 2 Seiten
DC Motor Controller Board Bedienungsanleitung   Flowserve DC Motor Controller Board User Manual, 4 Seiten
BUSwitch Bedienungsanleitung   Flowserve BUSwitch User Manual, 16 Seiten
ESP3 Electronic Servo Positioner Bedienungsanleitung   Flowserve ESP3 Electronic Servo Positioner User Manual, 4 Seiten
Electric Actuator for use with Fail Safe Uninterru Bedienungsanleitung   Flowserve Electric Actuator for use with Fail Safe Uninterruptable Power Supplies User Manual, 2 Seiten
E Series Electric Actuator Bedienungsanleitung   Flowserve E Series Electric Actuator User Manual, 2 Seiten
CPL Series CENTURA Bedienungsanleitung   Flowserve CPL Series CENTURA User Manual, 4 Seiten
SR Limit Switch Method 3-Position Control Bedienungsanleitung   Flowserve SR Limit Switch Method 3-Position Control User Manual, 2 Seiten
Automax Aviator Bedienungsanleitung   Flowserve Automax Aviator User Manual, 2 Seiten
DA Limit Switch Method 3-Position Control Bedienungsanleitung   Flowserve DA Limit Switch Method 3-Position Control User Manual, 2 Seiten
Pharos NAMUR Visual Indicator Bedienungsanleitung   Flowserve Pharos NAMUR Visual Indicator User Manual, 1 Seiten